minimum stay time in active range 7,5 seconds
water flows after leaving active range
adjustable flushing time from 0,5 to 15,5 seconds
adjustable active range setting
automatic hygiene flushing after 24 hours non-use
parameters adjustment by SLD 03 remote control
Operating data:
Dimension of stainless cover: 170 x 170 x 10 mm
Operating voltage: 24V DC external
Power input:
– 0,17 W (off position)
– 10 W (on position)
Active range: 0,3 – 0,7 m
Flow pressure: 0,1 – 0,8 MPa
Rate of flow: 12 l/min. (inf. data)
Water inlet: male thread G 3/4“
Water outlet: male thread G 3/4“